Brocade Communications Systems AA979A - StorageWorks SAN Switch 2/8V Reference Manual page 317

Brocade fabric os message reference guide (53-1000242-01, november 2006)
Hide thumbs Also See for AA979A - StorageWorks SAN Switch 2/8V:
Table of Contents

Advertisement

HMON System Messages
HMON-1001
Message
<timestamp>, [HMON-1001], <sequence-number>, FFDC, CRITICAL,
<system-name>, <Failure description>
Probable
Indicates that there was a problem reading an essential file containing configuration information from
Cause
the nonvolatile storage device. This could be the result of a missing file or a corrupt file system.
Recommended
Run the firmwareDownload command to reinstall the firmware to your switch.
Action
If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the
supportSave command and contact your switch service provider.
Severity
CRITICAL