ICPD System Messages
ICPD-1001
Message
<timestamp>, [ICPD-1001], <sequence-number>,, ERROR, <system-name>,
Failed to allocate memory: (<function name>).
Probable
Indicates that the specified function failed to allocate memory.
Cause
Recommended
Check memory usage on the switch using the memShow command.
Action
Reboot or power cycle the switch.
Severity
ERROR
ICPD-1002
Message
<timestamp>, [ICPD-1002], <sequence-number>,, ERROR, <system-name>,
Failed to initialize <module> rc = <error>.
Probable
Indicates that an initialization of a module within the ICPD failed.
Cause
Recommended
Download a new firmware version using the firmwareDownload command. Refer to the Fabric OS
Action
Command Reference for more information on this command.
Severity
ERROR
ICPD-1003
Message
<timestamp>, [ICPD-1003], <sequence-number>,, INFO, <system-name>,
iSCSI configuration has been committed by switch (<domain id>).
Probable
Indicates that iSCSI configuration has been committed by a remote switch in the fabric.
Cause