45
NBFS-1003
4 - Database Wait
5 - Full
If this error occurs repeatedly, it means the protocol implementation between two connected switches
has problems.
Recommended
Run the nbrStateShow command to check the neighbor state of the port listed in the message. If it is
Action
FULL, then this message can safely be ignored. Otherwise, run the portDisable and portEnable
commands to refresh the port.
Severity
ERROR
NBFS-1003
Message
<timestamp>, [NBFS-1003], <sequence-number>,, WARNING, <system-
name>, DB_XMIT_SET flag not set in state <current state name>, input
<state name>, port <portnumber>
Probable
Indicates that the database transmit set flag was not set for the specified input state on the specified port.
Cause
Neighbor finite state machine (NBFSM) states are as follows:
0 - Down
1 - Init
2 - Database Exchange
3 - Database Acknowledge Wait
4 - Database Wait
5 - Full
Recommended
No action is required. The Fabric OS auto recovers from this problem.
Action
Severity
WARNING