RAS System Messages
RAS-1001
Message
<timestamp>, [RAS-1001], <sequence-number>,, INFO, <system-name>,
First failure data capture (FFDC) event occurred.
Probable
Indicates that a failure happened and the failure data was captured.
Cause
Recommended
Run supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave command
Action
and contact your switch service provider.
Severity
INFO
RAS-1002
Message
<timestamp>, [RAS-1002], <sequence-number>,, WARNING, <system-
name>, First failure data capture (FFDC) maximum storage size (<log
size limit> MB) was reached.
Probable
Indicates that the maximum storage size for FFDC data capture is reached.
Cause
Recommended
Run the supportSave command and contact your switch service provider.
Action
Severity
WARNING
RAS-1003
Message
<timestamp>, [RAS-1003], <sequence-number>,, WARNING, <system-
name>, Audit message log is <____message____>.
Fabric OS Message Reference
Publication Number: 53-1000242-01
Chapter
53
53-1