HAMK System Messages
HAMK-1001
Message
<timestamp>, [HAMK-1001], <sequence-number>, FFDC, CRITICAL,
<system-name>, Warm Recovery Failed
Probable
The switch failed in the warm recovery.
Cause
Recommended
This message triggers a switch reboot automatically and attempts a cold recovery. Contact your switch
Action
service provider with the supportSave and haDump information.
Severity
CRITICAL
HAMK-1002
Message
<timestamp>, [HAMK-1002], <sequence-number>,, INFO, <system-name>,
Heartbeat down
Probable
Indicates that the active CP blade determined that the standby CP blade is down. This can be a result of
Cause
an operator-initiated action such as firmwareDownload, the standby CP blade being reset or removed,
or as a result of an error in the standby CP blade.
Recommended
Monitor the standby CP blade for a few minutes. If this message is due to a standby CP reboot, the
Action
message HAMK-1003 will display after the standby CP has completed the reboot successfully.
If the standby CP does not successfully connect to the active CP after 10 minutes, reboot the standby CP
blade by ejecting the blade and reseating it.
Severity
INFO
Fabric OS Message Reference