EM-1061
Message
<timestamp>, [EM-1061], <sequence-number>,, WARNING, <system-name>,
Synchronization halted. Remove all blades of type <Blade Type Id> or
upgrade your standby CP, then reboot or run haSyncStart.
Probable
A blade in the system is not supported by the release on the standby CP.
Cause
Recommended
Please remove all blades of this type or upgrade your standby CP. Once an appropriate action is taken,
Action
this CP must be rebooted or haSyncStart must be run successfully. Until this is done, the system will
remain out of synchronization.
Severity
WARNING
EM-1062
Message
<timestamp>, [EM-1062], <sequence-number>,, CRITICAL, <system-
name>, Blade in slot <Slot Id> faulted as it exceeds the maximum
support limit of <Limit> blades with Blade ID <Blade Type Id> in the
chassis.
Probable
Too many blades of a particular type are in the system.
Cause
Recommended
Please remove the faulted blade.
Action
Severity
CRITICAL
EM-1063
Message
<timestamp>, [EM-1063], <sequence-number>,, CRITICAL, <system-
name>, Blade in slot <Slot Id> faulted because it exceeds the
maximum support limit of <Limit> blades with Blade IDs <Applicable
blade Type IDs> in the chassis.
Probable
Too many blades of a set of particular types are in the system.
Cause
Recommended
Please remove the faulted blade.
Action