SEC-1159
Message
<timestamp>, [SEC-1159], <sequence-number>,, INFO, <system-name>,
Non_Reachable domain <Domain ID>.
Probable
Indicates that there has been a corruption during the distribution of the security database. This can only
Cause
occur when the primary FCS is distributing the security database to the other switches in the fabric and
local validation finds that there is an error in the security database. This is a rare occurrence.
Recommended
Run the secFabricShow command to verify that the fabric is still consistent. All the switches should be
Action
in the ready state. If a switch is in the error state, the database might not be correctly updated for that
specific switch.
Severity
INFO
SEC-1160
Message
<timestamp>, [SEC-1160], <sequence-number>,, INFO, <system-name>,
Duplicate port <port ID> in port list (<port list>).
Probable
Indicates that duplicate port member exists in the given portlist.
Cause
Recommended
Verify that there is no duplicate port member in the portlist.
Action
Severity
INFO
SEC-1163
Message
<timestamp>, [SEC-1163], <sequence-number>,, ERROR, <system-name>,
System is already in secure mode. Lockdown option cannot be applied.
Probable
Indicates that the lockdown option was attempted while the fabric is already in secure mode.
Cause
Recommended
Do not use the lockdown option with the secModeEnable command when switch is already in secure
Action
mode.