ZONE-1006
Message
<timestamp>, [ZONE-1006], <sequence-number>,, WARNING, <system-
name>, WARNING - WWN(<WWN number>) in HARD PORT zone <zone_name>.
Probable
Indicates that one or more devices are zoned as WWN devices and also zoned as <domain, portarea>
Cause
devices. The device(s) are used to specify zone members over separate zones.
Recommended
If hardware zoning enforcement is preferred, edit the zoning database to have the device zoned using
Action
only one specification type, either WWN or <domain, portarea>.
Severity
WARNING
ZONE-1007
Message
<timestamp>, [ZONE-1007], <sequence-number>,, INFO, <system-name>,
Ioctl(<function>) in (<error message>) at port (<port number>)
returns code (<error string>) and reason string (<reason string>)
Probable
Indicates that frame filter logic reported a failure during one of the IOCTL calls. The IOCTL call from
Cause
which the failure is reported is listed as part of the error message. This is usually a programming error
when adding CAM entries before the filter setup.
Recommended
There are two ways to avoid this problem.
Action
•
Avoid having too many hosts zoned with a set of target devices at a single port.
•
Avoid having too many zones directed at a single port group on the switch.
Severity
INFO
ZONE-1008
Message
<timestamp>, [ZONE-1008], <sequence-number>,, WARNING, <system-
name>, WARNING - port <port number> Out of CAM entries
Probable
Indicates that the total number of entries of S_ID CAM is above the limit while creating or adding a
Cause
zone group. The maximum number of CAM entries allowed depends on the ASIC.
Recommended
If hardware zoning enforcement is preferred, edit the zoning database to have zoned PIDs for that port.
Action
Severity
WARNING