CDR System Messages
CDR-1001
Message
<timestamp>, [CDR-1001], <sequence-number>,, ERROR, <system-name>,
Port <port number> port fault. Please change the SFP or check cable
Probable
Indicates a deteriorated SFP, an incompatible SFP pair, a faulty cable between peer ports, or the port
Cause
speed configuration does not match the capability of the SFP.
Recommended
Verify that you are using compatible SFPs on the peer ports.
Action
Verify that the SFPs have not deteriorated and that the Fibre Channel cable is not faulty. Replace the
SFPs or cable if necessary. If there is a speed configuration mismatch, replace the SFP with a
compatible one or change the configuration.
Severity
ERROR
CDR-1002
Message
<timestamp>, [CDR-1002], <sequence-number>, FFDC, ERROR, <system-
name>, Port <port number> chip faulted due to internal error.
Probable
Internal error. All the ports on the blade or switch will be disrupted.
Cause
Recommended
For a bladed system, issue the slotPowerOff and slotPowerOn commands on the blade to recover the
Action
system. For a non-bladed system, perform fastBoot on the switch to recover the system.
Severity
ERROR
Fabric OS Message Reference
Publication Number: 53-1000242-01
Chapter
6
6-1