3
BL-1018
BL-1018
Message
<timestamp>, [BL-1018], <sequence-number>,, INFO, <system-name>,
Slot <slot number> Initialization Completed
Probable
Indicates that the slot has completed initializing the ports.
Cause
Recommended
No action is required.
Action
Severity
INFO
BL-1019
Message
<timestamp>, [BL-1019], <sequence-number>,, INFO, <system-name>,
Slot <Slot number>, retry <Retry Number>, internal port retry
initialization, <List of internal ports retrying initialization>
Probable
Indicates that the slot had internal ports not online and that the system is retrying to bring the ports that
Cause
failed back online.
Recommended
No action is required.
Action
Severity
INFO
BL-1020
Message
<timestamp>, [BL-1020], <sequence-number>,, CRITICAL, <system-
name>, Switch timed out initializing the chips.
Probable
Indicates that the switch has failed to initialize the ASIC chips.
Cause
Recommended
Reboot or power cycle the switch.
Action
Run the systemVerification command to verify that the switch does not have hardware problems. Refer
to the Fabric OS Command Reference for more information on this command.
If the message persists, replace the switch.
Severity
CRITICAL