62
SWCH-1003
SWCH-1003
Message
<timestamp>, [SWCH-1003], <sequence-number>,, ERROR, <system-name>,
Slot ENABLED but Not Ready during recovery, disabling slot = <slot
number>(<return value>)
Probable
Indicates that the slot state has been detected as inconsistent during failover or recovery.
Cause
Recommended
On a SilkWorm 12000, 24000, or 48000 switch, run first the slotPowerOff and then the slotPowerOn
Action
commands.
On a SilkWorm 200E, 3250, 3850, 3900, or 4100 switch, reboot or power cycle the switch.
Severity
ERROR
SWCH-1004
Message
<timestamp>, [SWCH-1004], <sequence-number>,, ERROR, <system-name>,
Blade attach failed during recovery, disabling slot = <slot number>
Probable
Indicates that a blade has failed during failover or recovery.
Cause
Recommended
On a SilkWorm 12000, 24000, or 48000 switch, run first the slotPowerOff and then the slotPowerOn
Action
commands.
On a SilkWorm 200E, 3250, 3850, 3900, or 4100 switch, reboot or power cycle the switch.
Severity
ERROR
SWCH-1005
Message
<timestamp>, [SWCH-1005], <sequence-number>,, ERROR, <system-name>,
Diag attach failed during recovery, disabling slot = <slot number>
Probable
Indicates that the Diag blade attach has failed during failover or recovery.
Cause
Recommended
On a SilkWorm 12000, 24000, or 48000 switch, run first the slotPowerOff and then the slotPowerOn
Action
commands.
On a SilkWorm 200E, 3250, 3850, 3900, or 4100 switch, reboot or power cycle the switch.
Severity
ERROR
62-2