Brocade Communications Systems AA979A - StorageWorks SAN Switch 2/8V Reference Manual page 221

Brocade fabric os message reference guide (53-1000242-01, november 2006)
Hide thumbs Also See for AA979A - StorageWorks SAN Switch 2/8V:
Table of Contents

Advertisement

An E_Port has gone offline.
A principal link has segmented from the fabric.
Recommended
Verify that all ISL cables are properly connected at both ends. Verify that the SFP has not become faulty.
Action
An inexplicable fabric reconfiguration might be a transient error and might not require troubleshooting.
Severity
INFO
FW-1120
Message
<timestamp>, [FW-1120], <sequence-number>,, INFO, <system-name>,
<Label>, is between high and low boundaries(High=<High value>,
Low=<Low value>). Current value is <Value> <Unit>.
Probable
Indicates that the number of fabric reconfigures has changed from a value outside of the acceptable
Cause
range to a value within the acceptable range. The following occurrences can cause a fabric
reconfiguration:
Two switches with the same domain ID have connected to one another.
Two fabrics have joined.
An E_Port has gone offline.
A principal link has segmented from the fabric.
Recommended
No action is required. Respond to this message as is appropriate to the particular policy of the end-user
Action
installation.
Severity
INFO
FW-1121
Message
<timestamp>, [FW-1121], <sequence-number>,, INFO, <system-name>,
<Label>, value has changed(High=<High value>, Low=<Low value>).
Current value is <Value> <Unit>.
Probable
Indicates that the number of domain ID changes has changed. Domain ID changes occur when there is a
Cause
conflict of domain IDs in a single fabric and the principal switch has to assign another domain ID to the
switch.
Recommended
No action is required. Respond to this message as is appropriate to the particular policy of the end-user
Action
installation.
Severity
INFO
Fabric OS Message Reference
Publication Number: 53-1000242-01
25