Brocade Communications Systems AA979A - StorageWorks SAN Switch 2/8V Reference Manual page 167

Brocade fabric os message reference guide (53-1000242-01, november 2006)
Hide thumbs Also See for AA979A - StorageWorks SAN Switch 2/8V:
Table of Contents

Advertisement

FCPH System Messages
FCPH-1001
Message
<timestamp>, [FCPH-1001], <sequence-number>, FFDC, CRITICAL,
<system-name>, <function>: <failed function call> failed, out of
memory condition
Probable
Indicates that the switch is low on memory and failed to allocate new memory for a Fibre Channel
Cause
driver instance.
The function can only be " fc_create". This function creates a Fibre Channel driver instance.
The failed function call is "kmalloc_wrapper failed". This function call is for kernel memory allocation.
Recommended
A nonbladed switch will automatically reboot. For a bladed switch, the active CP blade will
Action
automatically fail over, and the standby CP will become the active CP.
Severity
CRITICAL
Fabric OS Message Reference
Publication Number: 53-1000242-01
Chapter
17
17-1

Advertisement

Table of Contents
loading

Table of Contents