47
PDM-1004
Probable
Indicates that a syntax error occurred when trying to launch the PDM process.
Cause
Recommended
Run the firmwareDownload command to reinstall the firmware.
Action
If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the
supportSave command and contact your switch service provider.
Severity
WARNING
PDM-1004
Message
<timestamp>, [PDM-1004], <sequence-number>,, WARNING, <system-
name>, Memory shortage
Probable
Indicates that the PDM process ran out of memory.
Cause
Recommended
Reboot or power cycle the switch.
Action
If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the
supportSave command and contact your switch service provider.
Severity
WARNING
PDM-1005
Message
<timestamp>, [PDM-1005], <sequence-number>,, WARNING, <system-
name>, FSS register failed
Probable
Indicates that the PDM failed to register to the FSS.
Cause
Recommended
Run the firmwareDownload command to reinstall the firmware.
Action
If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the
supportSave command and contact your switch service provider.
Severity
WARNING
PDM-1006
Message
<timestamp>, [PDM-1006], <sequence-number>,, WARNING, <system-
name>, Too many files in sync.conf
47-2
Fabric OS Message Reference
Publication Number: 53-1000242-01