Brocade Communications Systems AA979A - StorageWorks SAN Switch 2/8V Reference Manual page 455

Brocade fabric os message reference guide (53-1000242-01, november 2006)
Hide thumbs Also See for AA979A - StorageWorks SAN Switch 2/8V:
Table of Contents

Advertisement

SEC-1323
Message
<timestamp>, [SEC-1323], <sequence-number>,, INFO, <system-name>,
Key(s) \"<Key Name>\" ignored during configdownload
Probable
Indicates that the specified key is ignored during configdownload.
Cause
Recommended
Verify that the event was planned. If the event was planned, no action is required. If the event was not
Action
planned, take appropriate action as defined by your enterprise security policy.
Severity
INFO
SEC-1324
Message
<timestamp>, [SEC-1324], <sequence-number>,, INFO, <system-name>,
Fabric transaction failure. RCS error: <Error code>
Probable
Indicates that the RCS transaction failed with specified reason code.
Cause
Recommended
Verify that the event was planned. If the event was planned, no action is required. If the event was not
Action
planned, take appropriate action as defined by your enterprise security policy.
Severity
INFO
SEC-1325
Message
<timestamp>, [SEC-1325], <sequence-number>,, ERROR, <system-name>,
Security enforcement: Switch <switch WWN> connecting to port <Port
number> is not authorized to stay in fabric.
Probable
Indicates that due to an SCC policy violation, the switch is being disabled on the specified port.
Cause
Recommended
No action is required unless the switch must remain in the fabric. If the switch must remain in the fabric,
Action
add the switch WWN to the SCC policy, then attempt to join the switch with the fabric.
Severity
ERROR
Fabric OS Message Reference
Publication Number: 53-1000242-01