61
SULB-1035
Recommended
Run the firmwareShow command to verify the firmware versions. Also run the switchShow command
Action
to make sure the switch is enabled.
Severity
WARNING
SULB-1035
Message
<timestamp>, [SULB-1035], <sequence-number>,, ERROR, <system-name>,
An error has occurred during firmwaredownload.
Probable
Indicates that an error has occurred during the firmwareDownload. The error can be caused by
Cause
inconsistent AP blade firmware. It can also be caused by persistent storage hardware failure, or other
hardware failures.
Recommended
Try reseating the AP blade. Run firmwareDownload again. If the problem persists, contact your switch
Action
service provider.
Severity
ERROR
SULB-1036
Message
<timestamp>, [SULB-1036], <sequence-number>,, INFO, <system-name>,
<The Version being logged><Version String>
Probable
Indicates the firmware version running in the system. This is generally logged before download and
Cause
after download of the firmware to store version information.
Recommended
No action is required.
Action
Severity
INFO