47
PDM-1019
Probable
Indicates that a system call failed.
Cause
Recommended
Run the firmwareDownload command to reinstall the firmware.
Action
If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the
supportSave command and contact your switch service provider.
Severity
CRITICAL
PDM-1019
Message
<timestamp>, [PDM-1019], <sequence-number>,, WARNING, <system-
name>, File path or trigger too long
Probable
Indicates that one line of the pdm.conf file is too long.
Cause
Recommended
Run the firmwareDownload command to reinstall the firmware.
Action
If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the
supportSave command and contact your switch service provider.
Severity
WARNING
PDM-1020
Message
<timestamp>, [PDM-1020], <sequence-number>,, WARNING, <system-
name>, Long path name (<Path>/<File Name>), Skip
Probable
Indicates that the indicated file path name is too long. The maximum character limit is 49 characters.
Cause
Recommended
Use a path name with under 49 characters for the files to be replicated.
Action
Severity
WARNING
PDM-1021
Message
<timestamp>, [PDM-1021], <sequence-number>,, WARNING, <system-
name>, Failed to download area port map