9
EM-1014
Recommended
If the fruInfoSet command was being run, try the command again; otherwise, the update is
Action
automatically reattempted. If it continues to fail, try reseating the FRU.
If the message persists, replace the FRU.
Severity
ERROR
EM-1014
Message
<timestamp>, [EM-1014], <sequence-number>,, ERROR, <system-name>,
Unable to read sensor on <FRU Id> (<Return code>)
Probable
Indicates that the environmental monitor was unable to access the sensors on the specified FRU.
Cause
Recommended
Try reseating the FRU. If the message persists, replace the FRU.
Action
Severity
ERROR
EM-1015
Message
<timestamp>, [EM-1015], <sequence-number>,, WARNING, <system-name>,
Warm recovery failed (<Return code>)
Probable
Indicates that a problem was discovered when performing consistency checks during a warm boot.
Cause
Recommended
A reboot or power cycle is required to clear the situation.
Action
Severity
WARNING
EM-1016
Message
<timestamp>, [EM-1016], <sequence-number>,, WARNING, <system-name>,
Cold recovery failed (<Return code>)
Probable
Indicates that a problem was discovered when performing consistency checks during a cold boot.
Cause
Recommended
Monitor the switch.
Action