FSS System Messages
FSS-1001
Message
<timestamp>, [FSS-1001], <sequence-number>,, WARNING, <system-
name>, Component (<component name>) dropping HA data update
(<update ID>).
Probable
Indicates that an application has dropped a high availability (HA) data update.
Cause
Recommended
Run the haSyncStart command if this is a dual-CP system, or reboot the switch if it is a nonbladed
Action
system.
If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the
supportSave command and contact your switch service provider.
Severity
WARNING
FSS-1002
Message
<timestamp>, [FSS-1002], <sequence-number>,, WARNING, <system-
name>, Component (<component name>) sending too many concurrent HA
data update transactions (<dropped update transaction ID>)
Probable
Indicates that an application has sent too many concurrent high availability (HA) data updates.
Cause
Recommended
Run the haSyncStart command if this is a dual-CP system, or reboot the switch if it is a nonbladed
Action
system.
If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the
supportSave command and contact your switch service provider.
Severity
WARNING