Brocade Communications Systems AA979A - StorageWorks SAN Switch 2/8V Reference Manual page 363

Brocade fabric os message reference guide (53-1000242-01, november 2006)
Hide thumbs Also See for AA979A - StorageWorks SAN Switch 2/8V:
Table of Contents

Advertisement

Probable
Indicates that the configuration file sync.conf contains too many entries.
Cause
Recommended
Run the firmwareDownload command to reinstall the firmware.
Action
If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the
supportSave command and contact your switch service provider.
Severity
WARNING
PDM-1007
Message
<timestamp>, [PDM-1007], <sequence-number>,, WARNING, <system-
name>, File not created: <file name>
Probable
Indicates that the PDM process failed to create the specified file name.
Cause
Recommended
Run the firmwareDownload command to reinstall the firmware.
Action
If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the
supportSave command and contact your switch service provider.
Severity
WARNING
PDM-1008
Message
<timestamp>, [PDM-1008], <sequence-number>,, WARNING, <system-
name>, Failed to get the number of uports
Probable
Indicates that the PDM system call to getCfg failed.
Cause
Recommended
Run the firmwareDownload command to reinstall the firmware.
Action
If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the
supportSave command and contact your switch service provider.
Severity
WARNING
PDM-1009
Message
<timestamp>, [PDM-1009], <sequence-number>,, WARNING, <system-
name>, Can't update Port Config Data
Fabric OS Message Reference
Publication Number: 53-1000242-01
47
PDM-1007
47-3

Advertisement

Table of Contents
loading

Table of Contents