Brocade Communications Systems AA979A - StorageWorks SAN Switch 2/8V Reference Manual page 450

Brocade fabric os message reference guide (53-1000242-01, november 2006)
Hide thumbs Also See for AA979A - StorageWorks SAN Switch 2/8V:
Table of Contents

Advertisement

58
SEC-1308
SEC-1308
Message
<timestamp>, [SEC-1308], <sequence-number>,, INFO, <system-name>,
All Radius servers have failed to respond.
Probable
Indicates that all servers in the RADIUS configuration have failed to respond to a switch request within
Cause
the specified timeout.
Recommended
Verify that the switch has proper network connectivity to the specified RADIUS servers, and the servers
Action
are correctly configured.
Severity
INFO
SEC-1309
Message
<timestamp>, [SEC-1309], <sequence-number>,, INFO, <system-name>,
Waiting for RCS transaction to complete: <Wait time in seconds> secs
Probable
Indicates that Secure Fabric OS is still waiting for the RCS transaction to complete.
Cause
Recommended
Verify if there are any RCS or RTWR errors. If not, the transaction is still in progress.
Action
Severity
INFO
SEC-1310
Message
<timestamp>, [SEC-1310], <sequence-number>,, INFO, <system-name>,
Unable to determine data distribution limit of fabric. Please retry
later.
Probable
Unable to obtain the data distribution limit from all switches in the fabric. This may happen if the fabric
Cause
is reconfiguring or a new domain joined the fabric.
Recommended
Retry the command when the fabric is stable.
Action
Severity
INFO
58-56
Fabric OS Message Reference
Publication Number: 53-1000242-01

Advertisement