25
FW-1242
Probable
Indicates that the number of EE CRC errors has fallen below the low boundary. Invalid CRC messages
Cause
occur when the number of CRC errors in Fibre Channel frames for specific source ID (S_ID) and
destination ID (D_ID) pairs change. These messages might also be caused by dirty equipment,
temperature fluctuations, and aging equipment.
Recommended
No action is required. Respond to this message as is appropriate to the particular policy of the end-user
Action
installation. A low number of CRC errors means that the fabric is functioning normally. The CRC error
area of the End-to-End Performance Monitor class helps you tune your fabric. To reduce CRC
messages, experiment with alternative topologies and cabling schemes.
Severity
INFO
FW-1242
Message
<timestamp>, [FW-1242], <sequence-number>,, WARNING, <system-name>,
<Label>, is above high boundary(High=<High value>, Low=<Low
value>). Current value is <Value> <Unit>.
Probable
Indicates that the number of EE CRC errors has risen above the high boundary. Invalid CRC messages
Cause
occur when the number of CRC errors in Fibre Channel frames for specific source ID (S_ID) and
destination ID (D_ID) pairs change. These messages might also be caused by dirty equipment,
temperature fluctuations, and aging equipment.
Recommended
The CRC error area of the End-to-End Performance Monitor class helps the user tune the fabric. To
Action
reduce CRC errors, experiment with alternative topologies and cabling schemes. Clean equipment,
check temperatures, and replace old hardware.
Severity
WARNING
FW-1243
Message
<timestamp>, [FW-1243], <sequence-number>,, INFO, <system-name>,
<Label>, is between high and low boundaries(High=<High value>,
Low=<Low value>). Current value is <Value> <Unit>.
Probable
Indicates that the number of EE CRC errors has changed from a value outside of the acceptable range to
Cause
a value within the acceptable range. Invalid CRC messages occur when the number of CRC errors in
Fibre Channel frames for specific source ID (S_ID) and destination ID (D_ID) pairs change. These
messages might also be caused by dirty equipment, temperature fluctuations, and aging equipment.
Recommended
No action is required. Respond to this message as is appropriate to the particular policy of the end-user
Action
installation.
Severity
INFO