Brocade Communications Systems AA979A - StorageWorks SAN Switch 2/8V Reference Manual page 212

Brocade fabric os message reference guide (53-1000242-01, november 2006)
Hide thumbs Also See for AA979A - StorageWorks SAN Switch 2/8V:
Table of Contents

Advertisement

25
FW-1035
Severity
WARNING
FW-1035
Message
<timestamp>, [FW-1035], <sequence-number>,, WARNING, <system-name>,
<Label>, is above high boundary(High=<High value>, Low=<Low
value>). Current value is <Value> <Unit>.
Probable
Indicates that the temperature of the SFP has risen above the high boundary. Frequent fluctuations in
Cause
temperature might indicate a deteriorating SFP.
Recommended
Replace the SFP.
Action
Severity
WARNING
FW-1036
Message
<timestamp>, [FW-1036], <sequence-number>,, INFO, <system-name>,
<Label>, is between high and low boundaries(High=<High value>,
Low=<Low value>). Current value is <Value> <Unit>.
Probable
Indicates that the temperature of the SFP has changed from a value outside of the acceptable range to a
Cause
value within the acceptable range. Frequent fluctuations in temperature might indicate a deteriorating
SFP.
Recommended
No action is required.
Action
Severity
INFO
FW-1037
Message
<timestamp>, [FW-1037], <sequence-number>,, INFO, <system-name>,
<Label>, value has changed(High=<High value>, Low=<Low value>).
Current value is <Value> <Unit>.
Probable
Indicates that the receive power value of the SFP has changed. The receive performance area measures
Cause
the amount of incoming laser to help you determine if the SFP is in good working condition or not. If
the counter often exceeds the threshold, the SFP is deteriorating.
25-6
Fabric OS Message Reference
Publication Number: 53-1000242-01