TS System Messages
TS-1001
Message
<timestamp>, [TS-1001], <sequence-number>,, WARNING, <system-name>,
NTP Query failed: <error code>
Probable
Indicates that a network time protocol (NTP) query to the configured external clock server failed. Local
Cause
clock time on the principal or primary FCS switch is used for fabric synchronization.
This might be logged during temporary operational issues such as IP network connection issues to the
external clock server. If it does not recur, it can be ignored.
Recommended
Verify that the configured external clock server is available and functional. If that external clock server
Action
is not available, choose another.
Severity
WARNING
TS-1002
Message
<timestamp>, [TS-1002], <sequence-number>,, WARNING, <system-name>,
< Type of clock server used > Clock Server used instead of < Type of
clock server configured >: locl: 0x<code> remote: 0x<code>
Probable
Indicates that the fabric time synchronization distributed from the principal or primary FCS switch was
Cause
not sourced from the Type of clock server configured, instead, an alternate server was used, indicated by
Type of clock server used. The type of clock server used or configured might be either:
LOCL
Local clock on the principal or primary FCS switch
External
External NTP server address configured
This might be logged during temporary operational issues such as IP network connection issues to the
external clock server or if the fabric is configured for external time synchronization but the principal or
primary FCS does not support the feature. If the message does not recur, it should be ignored.