2
Technology > Main Controller > Controls > HDD Encryption/ Mirroring Kit (optional)
The following shows the statuses for each use case.
Case 1: Normally operated
Case 2: HDD-related error occurs because the system on the HDD cannot be read (other
than E602-2000 error)
Case 3: E602-2000 is triggered by failure in mutual authentication
Case 4: Unable to decode properly due to unmatched key for the encryption board
Correct
Correct
encryption
controller
board
two-way authentication
Correct
Correct HDD
controller
(Protection property)
It is not possible to decode.
Correct
Controller
encryption
not authorized
board
It is not possible two-way authentication
Encryption board
not authorized
● Actions against Troubles – Overview
Servicing
User data
Recovery
HDD
cleared
Replace HDDs
replacement
Encryption
cleared
Install HDD encryption
board
Kit
replacement
Main controller
cleared
Clear the key for HDD
2 replacement
data encryption kit
(SRAM)
Main controller
not cleared
N/A
1 replacement
Main controller
Information
After MN-CON clear
clear
held in SRAM
process is done
cleared
*1: How to Initialize Encryption Board
2
Technology > Main Controller > Controls > HDD Encryption/ Mirroring Kit (optional)
Encryption
Correct HDD
(Protection property)
Encryption
Correct HDD
(Protection property)
Correct HDD
(Protection property)
It is not possible to decode.
F-2-39
Action
1) Format the HDD
2) Install the system software
1) Replace encryption board
2) Initialize Encryption Board (see *1)
3) Format the HDD
4) Install the system
1) Initialize the encryption board (see *1)
2) Format the HDD
3) Install the system
N/A
MN-CON clear does not clear
authentication information; no work is
required specifically for HDD encryption kit
1. Initialize the encryption board via SST.
This step makes the disk unformatted (E602-0001 is triggered if the unformatted disk is
started).
2. Format the HDD and reinstall SYSTEM via SST.
When you start the HDD formatting, the message is automatically shown to confirm whether
to initialize the encryption board (Key Clear).
Key Clear will disable accesses to HDD data permanently. Cautions should be taken in Key
Clear execution.
<Points to Note in Initialization via SST>
The screen below is shown when you gain access to SST in safe mode due to E602-2000.
Poor board connection also causes this error. Check the board connection to seek error
recovery. Initialization of the encryption board will disable accesses to HDD data permanently.
Cautions should be taken in initialization.
<Points to Note in Initialization using USB>
The screen below is shown on the control panel when E602-2000 occurred and the machine
is started in safe mode using the USB flash memory with system data stored.
The message as shown in the figure below is displayed.
Select "0" when you are ready to initialize the encryption board.
T-2-16
F-2-40
Encryption board
error occurred.
Check connection
of the board.
Initialize
the board.
All data is deleted
at initialization.
[0]=Initialization
[other key]=exit
F-2-41
2-30