4
Parts Replacement and Cleaning > Fixing System > Cleaning the Shutter Cover > Procedure
Cleaning the Fixing Separation Guide
■ Preparations
1) Open the Right Lower Cover and Right Upper Cover.(Refer to page 4-175)
2) Remove the Fixing Unit.(Refer to page 4-167)
3) Remove the Film Unit.(Refer to page 4-169)
■ Procedure
1) Clean the Fixing Separation Guide with lint-free paper moistened with alcohol.
4
Parts Replacement and Cleaning > Fixing System > Cleaning the Shutter Cover > Procedure
■ Preparations
1) Open the Right Lower Cover and Right Upper Cover.(Refer to page 4-175)
2) Remove the Fixing Unit.(Refer to page 4-167)
■ Procedure
1) Change the direction of the Fixing Assembly. (Place it in the position where the Drawer
connector side faces up.)
2) Remove the harness.
• 3 connectors
• Harness Guide [A]
F-4-306
Cleaning the Shutter Cover
NOTE:
When installing/removing it, do not touch the Film Unit and Pressure Roller.
Connectors
x3
4-172
Drawer connector
Harness
[A]
F-4-307
4-172