Xerox workcentre 5335 series Service Manual page 1416

Table of Contents

Advertisement

Chain-
Link
Component
Description
077-071
Duplex Drive Motor
Drives Duplex Drive Motor with 2 phase excitation. max. speed. (Pull-in direction)
078-003
HCF Feed Motor: Feed
Drives the Motor in the Feed direction at a frequency of 2320PPS (307.5mm/s).
078-004
HCF Feed Motor: Lift
Drives the Motor in the Lift direction at a frequency of 3395PPS (450mm/s).
Drives it only when HCF Tray Level Sensor is Off.
Stops driving it if the sensor turns On while it is driving.
Does not drive it when HCF Tray In Sensor is Off.
078-093
HCF T/A Motor
Drives HCF T/A Roll at a speed of 330 mm/s.
091-001
BCR AC Bias
Enable the output of BCR AC Bias
091-002
BCR DC Bias
Enable the output of BCR DC Bias
091-003
BCR AC/DC Bias
Simultaneous output of BCR AC Bias, BCR DC Bias
091-004
BCR AC/DC Bias + Dev.
Simultaneous output of BCR AC Bias, BCR DC Bias and Dev. DC Bias
DC Bias
091-005
BCR AC/DC Bias + Dev.
Simultaneous output of BCR AC Bias, BCR DC Bias, Dev. DC Bias, and Drum Motor On
DC Bias + Drum Motor
093-001
Dev. DC Bias
Dev DC output Output value: NVM (Deve-DC I/O Check output value)
093-002
Dispense Motor
Output of Dispense Motor
094-001
BTR (-)
Outputs the BTR Bias (-).
094-002
BTR (+)
Outputs the BTR Bias (+).
094-003
DTS
Outputs the Detack Bias
General Procedures & Information
Component Control
Table 2 Output Component Control List - IOT/IIT/DADF/HCF
07/2011
6-20
BUS Updated 12/2011
Time-out conflicts
078-004
078-003
-
091-003,004,005
-
091-003,004,005
-
091-001, 002,004,005
-
091-001, 002,003,005; 093-001
-
091-001, 002,003,004; 093-001;
042-001, 002
-
091-004, 091-005
-
-
094-002
-
094-001
-
WorkCentre 5335 Family Service Documentation
Initial Issue

Advertisement

Table of Contents
loading

This manual is also suitable for:

Workcentre 5335 series

Table of Contents