CHAPTER 19 ALARM COMPARATOR
19.1

Outline of Alarm Comparator

This chapter provides an overview of the Alarm Comparator (also called Under/Overflow
voltage Detection), describes the register structure, modes and the operation of the
Alarm Comparator
■ Outline of Alarm Comparator
• The Alarm Comparator consists of an analog and a digital part.
• The analog part compares the input voltage with AVCC, AVSS or an internal reference voltage VREF
and generates digital output signals OUT1 and OUT2 for the digital part.
• If the voltage level at the input pin is higher than the lower threshold, OUT2 switches to high state.
• If the voltage level at the input pin is higher than the upper threshold, OUT1 switches to high state.
• The digital part uses OUT1 and OUT2 and generates an interrupt to CPU if the voltage is higher than the
upper threshold or lower than the lower threshold.
• The Alarm Comparator can be configured and controlled by the ACSRn and AECSRn registers.
• The Alarm Comparator can be switched between fast and slow comparison mode to reduce power
consumption
• The Alarm Comparator can be switched to power down mode.