MB96300 Super Series Hardware Manual
8.5.1
Reset Configuration Register (RCR)
The Reset Configuration Register (RCR) is used to assert a Software reset, configure the
low voltage reset and detector and to configure the Clock stop detection circuit.
■ Configuration of the Reset Configuration Register (RCR)
Figure 8.5-2 shows the configuration of the Reset Configuration Register (RCR) and Table 8.5-1 describes
the function of each bit.
CHAPTER 8 RESETS AND STARTUP