Advertisement

MB96300 Super Series Hardware Manual
■ Input Capture Unit source select
The source selection for ICU is done in the Input capture edge registers ICExy.
Address:
000041
H
X
: undefined value
R/W
: readable and writable
Figure 1.6-1 Input capture edge register ICE01
15
14
13
12
11
10
9
-
-
-
ICUS1
-
ICUS0
IEI1
-
-
-
R/W
-
R/W R/W R/W
8
Initial value
X X X 0 X 0 0 0
IEI0
B
bit8
IEI0
Input capture valid edge indication bit for ICU0
0
falling edge detected
1
rising edge detected
bit9
IEI1
Input capture valid edge indication bit for ICU1
0
falling edge detected
1
rising edge detected
bit10
ICUS0
Input capture source select for ICU0
0
The external pin IN0 is input source
1
USART0 is input source
bit11
-
read value is undefined, write always 0,
read-modify-write instructions are not affected
bit12
ICUS1
Input capture source select for ICU1
0
The external pin IN1 is input source
1
USART1 is input source
bit13-15
-
read value is undefined, write always 0,
read-modify-write instructions are not affected
CHAPTER 1 OVERVIEW
reserved bit
reserved bit