CHAPTER 14 16-BIT I/O TIMER
Figure 14.4-5 Block diagram of output selection (OCU module 1)
Compare
Control 2
CMOD1
CMP0EXT
CMOD0
Compare
Control 3
For OCU module 1, which requires a match with Output Compare Register 0 if CMOD[1:0] = "10
comparison result from module 0 is carried inside by the CMP0EXT signal. Of course, this does not apply to
module 0 itself. Here, no other register can be used but OCCP0 and OCCP1.
The equivalent situation applies to OCU module 3, where the result from module 2 is needed as CMP4EXT.
382
MB96300 Super Series Hardware Manual
OUT2
OUT3
" the