Siemens SINAMICS G150 Manual page 1062

Drive converter chassis
Hide thumbs Also See for SINAMICS G150:
Table of Contents

Advertisement

Signal targets for STW2_BM
Signal
Meaning
STW2.0
Command data set selection CDS, bit 0
STW2.1
Command data set selection CDS, bit 1
STW2.2
Drive data set selection DDS, bit 0
STW2.3
Drive data set selection DDS, bit 1
STW2.4
Drive data set selection DDS, bit 2
STW2.5
1 = Bypass ramp-function generator
STW2.6
Reserved
STW2.7
1 = Speed controller set integrator value
STW2.8
1 = Droop enabled
STW2.9
1 = Speed controller enabled
STW2.10
Reserved
1 = Torque controlled operation
STW2.11
0 = Speed controlled operation
STW2.12
Reserved
STW2.13
Reserved
STW2.14
Reserved
STW2.15
Controller slave sign-of-life Toggle bit
<1> Used in telegram 220.
<3> Only for Vector.
<2> Interconnection is not disabled.
<4> Only for "extended setpoint channel".
1
2
DO: SERVO, VECTOR
PROFIdrive - STW2_BM control word metal industry interconnection
<3>
<4>
<3>
<2>
<2>
<2>
<2>
p2081[15] = r2093.15
3
4
Interconnection
[Function diagram]
[Function diagram]
parameters
internal control word
signal target
p0810 = r2093.0
-
p0811 = r2093.1
-
p0820[0] = r2093.2
-
<2>
p0821[0] = r2093.3
-
<2>
p0822[0] = r2093.4
-
<2>
p1122[0] = r2093.5
-
-
-
p1477[0] = r2093.7
-
p1492[0] = r2093.8
-
p0856[0] = r2093.9
-
<2>
-
<2>
p1501[0] = r2093.11
-
<2>
-
-
<2>
<2>
-
-
5
6
fp_2426_54_eng.vsd
27.06.13 V04.07.00
<1>
PROFIdrive sampling time
Inverted
[8560]
-
[8560]
-
[8565]
-
[8565]
-
[8565]
-
-
-
-
-
-
-
[6030]
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
7
Function diagram
S120/S150/G130/G150
8
- 2426 -

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinamics g130

Table of Contents