enable inline-power slot
enable inline-power slot
enable inline-power slot <slot>
Description
Enables PoE power to the specified slot.
Syntax Description
slot
Enables inline power to specified slot.
Default
Enable.
Usage Guidelines
Disabling inline power to a slot immediately removes power to any connected PDs. By default, inline
power provided to all slots is enabled.
To deliver inline power to slots, you must reserve power for that slot using the
configure inline-
command. By default, each PoE module has 50 W of power reserved for inline
power budget slot
power.
NOTE
If your chassis has an inline power module and there is not enough power to supply a slot, that slot will not be
powered on; the slot will not function in data-only mode without enough power for inline power.
Disabling inline power using the
command does not affect the data traffic
disable inline-power
traversing the slot. And, disabling the slot using the
command does not affect the inline
disable slot
power supplied to the slot.
Example
The following command makes inline power available to slot 3:
enable inline-power slot 3
History
This command was first available in ExtremeWare XOS 11.1.
433