Power Over Ethernet Commands

configure inline-power disconnect-precedence

configure inline-power disconnect-precedence [deny-port | lowest-priority]
Description
Configures the disconnect precedence priority for the switch when a new PD is detected and the
measured inline power for that slot is within 19 W or the slot's PoE power budget.
Syntax Description
deny-port
lowest-priority
Default
Deny-port.
Usage Guidelines
You configure this parameter for the entire switch; you cannot configure this per slot or per port.
If the power supplied to the PDs on a slot exceeds the power that was budgeted for that slot, the system
disconnects power to one or more ports to prevent power overload. Refer to
budget slot
You configure the switch to either deny power to the next PD that requests power on that slot,
regardless of the priority, or to disconnect those PDs on ports with lower priorities until there is enough
power for the new PD. If you select this argument and you did not configure port priorities or if several
ports have the same priority, the switch withdraws power (or disconnects) those ports with the highest
port number (s). Refer to
the PoE priority for the ports.
The default value is deny-port. So, if you do not change the default value and the slot's power is
exceeded, the next PD requesting power will not be connected.
When the setting is lowest priority, the switch continues dropping ports with the lowest configured PoE
port priorities, or the highest port number in the case of equal PoE port priorities, until there is enough
power for the requesting PD.
Example
The following command sets the switch to withdraw power from the lowest-priority port(s) on the
switch:
configure inline-power disconnect-precedence lowest-priority
416
Specifies power be denied to PD requesting power, regardless of priority.
Specifies power be withdrawn from lowest-priority port(s) when next PD
requesting power connects.
for information on configuring and modifying the power budgeted for each slot.
configure inline-power priority ports
configure inline-power
for information on configuring
ExtremeWare XOS 11.3 Command Reference