Commands for Status Monitoring and Statistics
To view the temperature of the fan trays installed in the BlackDiamond 10K switch, use the following
command:
show fans {detail}
Example
Depending on the platform, the following command displays the temperature of various switch
components:
show temperature
The following is sample output from a modular switch:
Field Replaceable Units
------------------------------------------------
Slot-1
: 10G6X
Slot-2
: G60X
Slot-3
:
Slot-4
:
Slot-5
:
Slot-6
: G60X
Slot-7
: G60X
Slot-8
:
MSM-A
: MSM-1XL
MSM-B
: MSM-1XL
PSUCTRL-1
:
PSUCTRL-2
:
Temp Range: -10.00 (Min), 0.00-50.00 (Normal), 60.00 (Max)
The following is sample output from a Summit X450 switch:
Field Replaceable Units
------------------------------------------------
Switch
: SummitX450-24x
XGM-2xn-1
:
Temp Range: -10.00 (Min), 0.00-60.50 (Normal), 62.90 (Max)
History
This command was first available in an ExtremeWare XOS 10.1.
Information about the power controller(s), a component status column, and the minimum, normal, and
maximum temperature ranges of the components was added to the
ExtremeWare XOS 11.0.
Information about the XGM-2xn card was added to the
11.2.
Platform Availability
This command is available on all platforms.
568
Temp (C)
Status
36.37
Normal
35.31
Normal
34.68
Normal
34.31
Normal
31.37
Normal
29.75
Normal
29.00
Normal
Temp (C)
Status
42.50
Normal
show temperature
output in
show temperature
output in ExtremeWare XOS
ExtremeWare XOS 11.3 Command Reference