Power Over Ethernet Commands

configure inline-power usage-threshold

configure inline-power usage-threshold <threshold>
Description
Sets the inline power usage SNMP event threshold.
Syntax Description
threshold
Default
70.
Usage Guidelines
This command sets the threshold for generating an SNMP event and an Event Management System
(EMS) message when the measured power for a PoE module compared to the budgeted power for that
slot exceeds a certain value. The configured threshold value initiates the event and message once that
percentage of the budgeted power is being used.
The PoE threshold applies only to the percentage per slot of measured to budgeted power use; it does
not apply systemwide.
The system generates an additional SNMP event and EMS message once the power usage falls below the
threshold again; once the condition clears.
Example
The following command sets the inline power usage alarm threshold at 75%:
configure inline-power usage-threshold 75
History
This command was first available in ExtremeWare XOS 11.1
Platform Availability
This command is available only on the G48P module installed in the BlackDiamond 8800 family of
switches.
422
Specifies the percentage of budgeted power used on any PoE module that causes
the system to send an SNMP event and create a log message. The range 1 to 99;
the default value is 70.
ExtremeWare XOS 11.3 Command Reference