reset inline-power ports

reset inline-power ports <port_list>
Description
Power cycles the specified ports.
Syntax Description
portlist
Default
N/A.
Usage Guidelines
This command power cycles the specified ports. Ports are immediately disabled and then re-enabled,
allowing remote PDs to be power-cycled.
This command affects only inline power; it does not affect network connectivity for the port(s).
Example
The following command resets power for port 4 on slot 3:
reset inline-power ports 3:4
History
This command was first available in ExtremeWare XOS 11.1.
Platform Availability
This command is available only on the G48P module installed in the BlackDiamond 8800 family of
switches.