configure sys-health-check interval

configure sys-health-check interval <interval>
Description
Configures the frequency of sending backplane diagnostic packets and the polling interval.
Syntax Description
interval
Default
Depending upon your platform, the following defaults apply:
BlackDiamond 10K switch:
If backplane diagnostics packets are enabled on a particular slot, the default for sending packets
and for polling is 6 seconds on that slot.
If only polling occurs, the default polling interval is 60 seconds (
BlackDiamond 8800 family of switches:
If backplane diagnostics are enabled on a particular slot, the default for sending packets is 5
seconds on that slot.
The polling interval is always 5 seconds (this is a not a user-configured parameter).
Usage Guidelines
Use this command with the guidance of Extreme Networks Technical Support personnel.
The system health checker tests I/O modules and the backplane by forwarding backplane diagnostic
packets. On the BlackDiamond 10K switch, additional checking for the validity of these packets is
completed by performing a checksum. Use this command to configure the amount of time it takes for
the packets to be forwarded and returned to the MSM.
To enable backplane diagnostic packets, use the
With backplane diagnostic packets enabled on a specific slot, the
ExtremeWare XOS 11.3 Command Reference
BlackDiamond 10K switch—Specifies the frequency of sending backplane
diagnostic packets and polling the ASIC counters.
• If backplane diagnostic packets are enabled on a particular slot, the default
value for sending diagnostic packets and polling the ASIC counters is 6
seconds on that slot.
• If only polling occurs (this is the system default), the default value is 60
seconds. The polling interval is interval*10 seconds.
BlackDiamond 8800 family of switches—Specifies the frequency of sending
backplane diagnostic packets.
• If backplane diagnostic packets are enabled on a particular slot, the default
value for sending diagnostic packets is 5 seconds on that slot.
• If only polling occurs (this is the system default), the default value is
5 seconds. (The polling interval is not a user-configured parameter, and
polling always occurs.)
enable sys-health-check slot <slot>
configure sys-health-check interval
*10 seconds).
interval
option of the
interval
configure
command.