Unconfigure Inline-Power Usage-Threshold - Extreme Networks ExtremeWare XOS Command Reference Manual

Version 11.3
Hide thumbs Also See for ExtremeWare XOS:
Table of Contents

Advertisement

Power Over Ethernet Commands

unconfigure inline-power usage-threshold

unconfigure inline-power usage-threshold
Description
Unconfigures the inline power usage alarm threshold and returns threshold to the default value of 70%.
Syntax Description
This command has no arguments or variables.
Default
70.
Usage Guidelines
This command unconfigures the PoE usage threshold setting for initiating SNMP event and EMS
messages and returns the switch's inline power usage threshold for to 70%. The system initiates an
event and message once that percentage of the budgeted power is being used.
The PoE threshold applies only to the percentage per slot of measured to budgeted power use; it does
not apply to the entire switch.
The system generates an additional SNMP event and EMS message once the power usage falls below the
threshold again; once the condition clears.
Example
The following command resets the inline power usage alarm threshold to 70%:
unconfigure inline-power usage-threshold
History
This command was first available in ExtremeWare XOS 11.1
Platform Availability
This command is available only on the G48P module installed in the BlackDiamond 8800 family of
switches.
454
ExtremeWare XOS 11.3 Command Reference