Extreme Networks ExtremeWare XOS Command Reference Manual page 469

Version 11.3
Hide thumbs Also See for ExtremeWare XOS:
Table of Contents

Advertisement

configure log filter events match
Example
By default, all log targets are associated with the built-in filter, DefaultFilter. Therefore, the most
straightforward way to send additional messages to a log target is to modify DefaultFilter. In the
following example, the command modifies the built-in filter to allow incidents in the STP component,
and all subcomponents of STP, of severity critical, error, warning, notice and info. For any of these
events containing a physical port number as a match parameter, limit the incidents to only those
occurring on physical ports 3, 4 and 5 on slot 1, and all ports on slot 2:
configure log filter DefaultFilter add events stp severity info match ports 1:3-1:5,
2:*
If desired, issue the
command to restore the DefaultFilter back to its
unconfigure log DefaultFilter
original configuration.
History
This command was first available in ExtremeWare XOS 10.1.
New parameter
values, including
and
were added in ExtremeWare XOS 11.0 and
<type>
esrp
eaps
11.1.
Support for IPv6 addresses was added in ExtremeWare XOS 11.2.
Platform Availability
This command is available on all platforms.
469
ExtremeWare XOS 11.3 Command Reference