show temperature

show temperature
Description
Depending on the platform, this command displays the current temperature of the I/O modules,
management modules, power supply controllers, XGM-2xn card, and the switch.
Syntax Description
This command has no arguments or variables
Default
N/A.
Usage Guidelines
Depending on the software version running on your switch or your switch model, additional or
different temperature information might be displayed.
Modular Switches Only. Use this command to display the temperature in Celsius and the current status
of the following installed components in the switch:
Management modules (MSM)
I/O modules
Power controllers
The switch monitors the temperature of each component and generates a warning if the temperature
exceeds the normal operating range. If the temperature exceeds the minimum/maximum limits, the
switch shuts down the overheated module.
Summit X450 Switch Only. Use this command to display the temperature in Celsius and the current
status of the following components:
Switch
XGM-2xn card
The switch monitors its temperature and generates a warning if the temperature exceeds the normal
operating range. If the temperature exceeds the maximum limit, the
switch in an
OPERATIONAL (Overheat)
state due to overheat.
Displaying the Temperature of Other Installed Components—Modular Switches Only. You can also view the
temperature of the power supplies and the fan trays in the switch.
To view the temperature of the power supplies installed in a modular switch, use the following
command:
show power {<ps_num>} {detail}
ExtremeWare XOS 11.3 Command Reference
mode, and the
show temperature
show temperature
output indicates the
show switch
output indicates an error