ABB IRB 1100 Product Manual page 163

Hide thumbs Also See for IRB 1100:
Table of Contents

Advertisement

2
Refitting the axis-6 motor
1
2
3
Product manual - IRB 1100
3HAC064992-001 Revision: L
Action
Refit the cable bracket.
Action
For robots with protection type Clean Room:
Clean the joints that have been opened and wipe
the parts free from particles with spirit on a lint
free.
Check that:
all assembly surfaces are clean and without
damages
the motor is clean and undamaged.
Orient the motor correctly and fit it into the lower
arm.
Tip
Leave the connectors FB5 and FB6 accessible
from the process hub and the connectors MP5
and MP6 accessible from wrist side.
© Copyright 2019-2022 ABB. All rights reserved.
5.3.1 Replacing the upper cable package
Note
Screw: M2.5x6 12.9 Lafre
2C2B/FC6.9 (2 pcs)
Tightening torque: 0.6 Nm
xx1800003002
Note
Motor orientation: orient the motor
according to the figure below, in
regard to the encircled motor con-
nector.
xx1800003023