5
Concluding procedure
1
2
3
Product manual - IRB 1100
3HAC064992-001 Revision: L
Action
Apply grease to the covers that have contacting
area with the cable package.
Refit the covers.
Lower arm cover
Lower arm support cover
Action
For robots with protection type Clean Room:
Clean and paint the joints that have been opened.
See
Cut the paint or surface on the robot before
replacing parts on page 123
Note
After all repair work, wipe the Clean Room robot
free from particles with spirit on a lint free cloth.
Recalibrate the robot.
DANGER
Make sure all safety requirements are met when
performing the first test run.
© Copyright 2019-2022 ABB. All rights reserved.
5 Repair
5.7.3 Replacing the axis-3 motor
Continued
Note
Screw: M3x8 12.9 Lafre
2C2B/FC6.9
Tightening torque: 1.2 Nm
xx1800003608
Note
Calibration is detailed in section
Calibration on page
711.