Refitting the axis-1 motor
1
2
3
4
Product manual - IRB 1100
3HAC064992-001 Revision: L
Action
For robots with protection type Clean Room:
Clean the joints that have been opened and wipe
the parts free from particles with spirit on a lint
free.
Check that:
all assembly surfaces are clean and without
damages
the motor is clean and undamaged.
Check the cooling pad.
Replace if damaged.
Install the timing belt to the motor pulley and
verify that the belt runs correctly in the groove of
the pulley.
© Copyright 2019-2022 ABB. All rights reserved.
5 Repair
5.4.2 Replacing the swing
Continued
Note
Cooling pad for axis-1 and -2 mo-
tors: 3HAC071020-001
xx1800003602
xx1800003085
Continues on next page