ABB IRB 1100 Product Manual page 509

Hide thumbs Also See for IRB 1100:
Table of Contents

Advertisement

Spare part
Gasket for swing cover
Gasket for swing support cover
Cooling pad for axis-1 and -2 mo-
tors
Washer
Required tools and equipment
Equipment
Standard toolkit
Calibration tool box, Axis Calibra-
tion
24 VDC power supply
Sonic tension meter
Dynamometer
Required consumables
Consumable
Cable straps
Grease
Sealing compound
Product manual - IRB 1100
3HAC064992-001 Revision: L
Article number
3HAC061959-003
3HAC065317-001
3HAC071020-001
3HAC063985-001
Article number
-
3HAC074119-001
-
-
-
Article number
-
3HAC029132-001
3HAC026759-002
© Copyright 2019-2022 ABB. All rights reserved.
5 Repair
5.7.2 Replacing the axis-2 motor
Continued
Note
Used with protection class IP67
and protection type Clean Room.
Replace if damaged.
Used with protection class IP67
and protection type Clean Room.
Replace if damaged.
Cooling pads are wear parts. One
cooling pad sheet contains 6
pieces of small pad.
Replace if damaged with one
piece each time.
9x4.3x1, Steel
Note
Content is defined in section
Standard toolkit on page
Delivered as a set of calibration
tools.
Required if Axis Calibration is the
valid calibration method for the
robot.
The tool box also includes a
unique calibration pin for IRB
1100 to be fitted to the tool flange
during calibration of axis 6.
Used to release the motor brakes.
Used for measuring the timing
belt tension.
Used for measuring the timing
belt tension.
Note
FM 222
Sikaflex 521 FC
For robots with protection type
Clean Room.
Continues on next page
757.
509

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents