5 Repair
5.3.1 Replacing the upper cable package
Continued
3
Continues on next page
154
Action
Apply a little Loctite 243 to the locking screw and
refit the locking screw.
Note
Make sure the locking screw header is parallel
with flange surface.
Note
If there is locking liquid residues on the screw or
screw hole, please clean it before refitting.
Remove residual locking liquid after refitting.
© Copyright 2019-2022 ABB. All rights reserved.
Note
Screw: M3x8 (1 pcs)
Tightening torque: 0.4 Nm
Valid for IRB 1100-4/0.475
xx1800003031
Valid for IRB 1100-4/0.58
xx1800003001