5 Repair
5.7.5 Replacing the axis-5 motor
Continued
3
4
Removing the axis-5 motor
1
2
3
Continues on next page
554
Action
Access the connector FB5 from the process hub
and disconnect the connector.
Disconnect the connector.
MP5
Action
DANGER
Make sure that all supplies for electrical power,
hydraulic pressure, and air pressure are turned
off.
CAUTION
For robots with protection type Clean Room
Always cut the paint with a knife and grind the
paint edge when disassembling parts of the robot!
See
Cut the paint or surface on the robot before
replacing parts on page
123.
CAUTION
Removing motors will release axes. This means
the axes can fall down.
Make sure axes are well supported before remov-
ing motors.
© Copyright 2019-2022 ABB. All rights reserved.
Note
xx1800002950
xx1800002993
Note
Product manual - IRB 1100
3HAC064992-001 Revision: L

Hide quick links: