3
4
Separating the upper cable package from the housing
1
2
Product manual - IRB 1100
3HAC064992-001 Revision: L
Action
Remove the housing cover.
Disconnect the motor connectors.
FB4
MP4
Action
DANGER
Make sure that all supplies for electrical power,
hydraulic pressure, and air pressure are turned
off.
CAUTION
For robots with protection type Clean Room
Always cut the paint with a knife and grind the
paint edge when disassembling parts of the robot!
See
Cut the paint or surface on the robot before
replacing parts on page
123.
© Copyright 2019-2022 ABB. All rights reserved.
5.3.1 Replacing the upper cable package
Note
xx1800003011
xx1800003012
Note
Continues on next page
5 Repair
Continued
149