5 Repair
5.7.3 Replacing the axis-3 motor
Continued
3
4
5
6
Continues on next page
526
Action
Remove the lower arm support cover.
Remove the connector plate.
CAUTION
Be aware of the cablings that are attached to the
connector plate! The connector plate cannot be
removed completely until the connectors are re-
move from the plate, as shown in following step.
Slide the connectors out of the connector plate
and disconnect the connectors.
FB3
MP3
Tip
Take photos of the connector and cable position
before disconnecting them, to have as a reference
when reconnecting.
Remove the cable bracket.
© Copyright 2019-2022 ABB. All rights reserved.
Note
xx1800003003
xx1800003004
xx1800003005
xx1800003006