ABB IRB 1100 Product Manual page 587

Hide thumbs Also See for IRB 1100:
Table of Contents

Advertisement

4
5
6
Opening the connector interface plate
1
2
Product manual - IRB 1100
3HAC064992-001 Revision: L
Action
Remove the SMB cover attachment screws and
carefully open the cover.
CAUTION
Clean cover from metal residues before opening.
Metal residues can cause shortage on the boards
which can result in hazardous failures.
CAUTION
There are cabling attached to the cover. The
cover cannot be removed completely until the
connectors are removed.
Disconnect the connectors.
SMB.P7
SMB.J1
SMB.J2
Tip
Take photos of the connector and cable position
before disconnecting them, to have as a reference
when reconnecting.
Remove the SMB cover completely from the base.
Action
DANGER
Make sure that all supplies for electrical power,
hydraulic pressure, and air pressure are turned
off.
CAUTION
For robots with protection type Clean Room
Always cut the paint with a knife and grind the
paint edge when disassembling parts of the robot!
See
Cut the paint or surface on the robot before
replacing parts on page
123.
© Copyright 2019-2022 ABB. All rights reserved.
5.8.1 Replacing the axis-1 gearbox
Note
xx1800002467
xx1800002468
Note
Continues on next page
5 Repair
Continued
587